The evidence library

Every claim on the site with the study, guideline or manual it comes from: WHO, EPA, CDC, ASHRAE, Indoor Air, Building and Environment, Daikin/Mitsubishi/LG manuals. Rated strong / moderate / limited.

69sourced claims
65unique sources
32strong
14topics

The most important

strong evidenceWHO concludes that indoor dampness and mould significantly increase the risk of respiratory symptoms, allergies and asthma.

The 2009 WHO indoor air quality guideline reviewed hundreds of epidemiological studies and found sufficient evidence linking dampness/mould with respiratory symptoms, allergies and asthma, plus immune perturbation. WHO states that the most important means of prevention is avoiding persistent dampness and microbial growth on interior surfaces. A split air conditioner contains exactly such surfaces: the evaporator, the drain pan and the blower stay wet for hours. Periodic sanitising of the indoor unit is therefore a preventive measure, not just comfort.

Sources (2)
strong evidenceMould does not grow below roughly 80% surface relative humidity, but the cold surfaces inside an air conditioner constantly exceed this threshold.

WHO notes that mould fungi do not grow below about 80% relative humidity at the material surface, and for soiled materials the critical threshold drops to 75–80%. In an indoor AC unit, the evaporator works below the dew point, so it is covered in condensate (100% local humidity) whenever the unit is cooling. Dust settled on the fins and blower provides the food, and the moisture the growing conditions. This is why mould appears inside the unit even in a dry, clean home.

Sources (1)
strong evidenceMould spores are everywhere in air and dust and cannot be fully eliminated; the goal is moisture control and cleaning surfaces.

EPA states it is impossible to get rid of all mould spores indoors, since they float in the air and are found in house dust. Spores only become a problem when they find moisture and food – and a wet, dusty evaporator is the ideal place. The practical conclusion for a split unit: what matters is not how many spores enter, but how often dust and biofilm are removed from the wet surfaces. Mechanical cleaning of the fins and blower breaks this cycle.

Sources (1)
strong evidenceMould remains allergenic even when dead, so merely 'killing' it with a spray does not solve the problem – it must be physically removed.

EPA's mould remediation guide states that mould is allergenic whether dead or alive, and some moulds may be toxic. EPA therefore focuses on physical removal, not sterilisation. For an air conditioner, an 'antibacterial' spray through the grille may kill some organisms but leaves the biofilm layer, spores and allergenic fragments on the blower and fins, from where they are blown into the room. Proper sanitising means pressure washing and rinsing, then disinfecting.

Sources (1)
strong evidenceEPA advises not to run an HVAC system you know or suspect is mould-contaminated, because it spreads mould throughout the home.

Both the EPA home guide and the schools/commercial guide contain the same recommendation: do not run the HVAC system if it is mould-contaminated, since it can spread mould throughout the building. In a split unit the cross-flow fan pushes air directly over the evaporator and blower, so any mould colony becomes a spore source for the room. If you see black spots on the outlet louvres or smell mould at start-up, it is safer to switch the unit off and schedule sanitising. This matters most in bedrooms and children's rooms.

Sources (2)
strong evidenceWhen a contaminated air conditioner starts, airborne fungal concentration in the room can jump from 40–920 to 5,500–100,000 CFU/m³.

The Indoor Air study (Shiraishi et al., 2023) on Japanese household units measured a massive jump in airborne fungi immediately after switching the unit on: from a background of 40–920 CFU/m³ to 5,500–100,000 CFU/m³. This is exactly the 'burst' of odour and spores customers notice in the first minutes of operation. The main source is not the filter but the blower fan and the outlet vanes located downstream of the evaporator. Pressure washing these parts reduced fungal abundance by over 99%.

Sources (1)
strong evidenceThe blower (cross-flow fan) is the most fungus-contaminated component of a split unit, more than the filter or the front of the evaporator.

Fungal DNA analysis in Shiraishi et al. (2023) found high levels in all internal parts, but the blower fan was the most contaminated, followed by the air outlet vanes – both downstream of the heat exchanger where air is cold and saturated. Dominant taxa were Cladosporium, Toxicocladosporium, Aureobasidium, Aspergillus and Rhodotorula. The authors even recommend sampling the blower rather than the filter to assess contamination. In practice, a 'cleaning' limited to filters and the evaporator face leaves the main spore source untouched.

Sources (1)
strong evidenceWashing with alkaline detergent, brushing and high-pressure rinsing reduces fungi inside the unit by more than 99%.

In the Indoor Air (2023) study, the sanitising procedure – applying alkaline detergent, brushing and rinsing internal parts with pressurised water – reduced fungal abundance by more than 99% across all components, including the blower. This confirms that the mechanical method (pressure washing with a cleaning solution, then rinsing) is effective, unlike spraying an aerosol through the grille. For a wall-mounted split, the procedure is done in place with a collection cover/bag, without removing the unit. The study provides the scientific backing for what we call 'complete sanitising'.

Sources (1)