Glossary

The terms you hear from the technician or read in studies, explained simply.

Explanatory diagramIndoor unit components
Indoor unit components
  1. Filters retain some airborne particles.
  2. The coil transfers heat; during cooling it can collect condensate.
  3. The blower moves air.
  4. The pan collects condensate for drainage.
Explanatory diagramHow air moves through a split unit
How air moves through a split unit
  1. Room air enters the unit.
  2. Air passes through the filter and coil.
  3. The fan returns it to the room.

A typical split recirculates air; it does not replace outdoor-air ventilation.

Collection cover / bag Husă / sac de colectare
Double-layer waterproof sheet sealed around the indoor unit that collects the wash water and sends it through a hose into a bucket; allows pressure washing on the wall without dismantling.
Evaporator (indoor coil) Vaporizator (baterie interioară)
The aluminium-fin heat exchanger in the indoor unit on which air cools and condenses; wet for hours after shutdown, it is the main place where mould grows.
Cross-flow blower Turbină tangențială
The long finely bladed cylinder that pushes air into the room; it loads with moisture-bound dust and turns black; a blower with 1 mm of build-up loses 20–30% of airflow.
Drain pan and condensate hose Tavă și furtun de condens
Collect and drain condensed water; clogged with biological slime they cause smell and dripping; flushed at every sanitising.
Biofilm Biofilm
The thin, sticky layer of bacteria and mould that forms on the unit's wet surfaces; it resists drying and sprays and is removed only mechanically, by washing.
MVOC (microbial volatile organic compounds) MVOC (compuși organici volatili microbieni)
The gases produced by the bacteria and mould in the biofilm; they are the 'cellar' smell you notice when the unit starts.
Spores Spori
The mould's 'seeds', a few microns in size, leaving the unit especially at start-up; even dead spores remain allergenic.
CFU (colony-forming units) UFC (unități formatoare de colonii)
The unit in which laboratories measure how contaminated a surface is; above 500 CFU/cm² is considered dirty, and drain pans reach over 10,000.
Alkaline cleaning solution Soluție de curățare alcalină
The first solution: dissolves grease and bound dust on fins and blower; left to work and fully rinsed under pressure.
Sanitising solution Soluție de igienizare
The second solution, applied to already clean surfaces; reduces remaining bacteria and fungi; does not replace washing.
Service check Revizie
The annual check of the unit: filters, coil, blower, pan, drain, temperature split, noise, outdoor unit, photo report; does not include refrigerant circuit work.
Temperature split (delta T) Diferența de temperatură (delta T)
The difference between return and supply air; normally 8–12 °C in cooling; a dirty unit shows a small split and weak airflow.
Relative humidity Umiditate relativă
The percentage of water vapour in the air; comfort and health between 40 and 60%; above 60% dust mites thrive, above 80% on surfaces mould grows.
Dust mites Acarieni
Dust-dwelling micro-organisms producing strong allergens; they multiply at humidity above 50–60%.
Poplar fluff Puf de plop
The fluffy May–June seeds that clog the outdoor unit coil in Bucharest; the reason we also wash the outdoor unit.
Outdoor unit Unitate exterioară
The balcony or façade unit with compressor and coil; when the coil is clogged, consumption rises and the unit shuts down on protection in heatwaves.
Ceiling cassette Casetă de tavan
Indoor unit mounted in the false ceiling with 4-way discharge and a condensate pump; sanitised with a square cover.
Ducted unit Unitate de duct
Concealed ceiling unit distributing air through ductwork; cleaned through the access hatch.
Multi-split Multi-split
One outdoor unit serving 2–5 indoor units; each indoor unit is sanitised separately, the outdoor one once.
BTU BTU
The commercial capacity unit: 9,000 BTU ≈ 2.6 kW (15–20 m² room), 12,000 ≈ 3.5 kW (25–30 m²), 18,000 ≈ 5.2 kW, 24,000 ≈ 7 kW.
Fan mode (unit drying) Mod ventilație (uscare aparat)
Running the unit with the fan only, 30–60 minutes after cooling stops or before winter, so the evaporator dries and mould does not grow.
Job sheet Fișă de intervenție
The document with before/after photos, what was done, the unit's state and the recommendation for the next visit; you receive it on WhatsApp or by email.